Login required to View Regulations

Sign In or Register Now.  Registration is fast and free!

 
§250.525 — When am I required to take action from my casing diagnostic test?

You must take action if you have any of the following conditions:

 
(a)
Any fixed platform well with a casing pressure exceeding its maximum allowable wellhead operating pressure (MAWOP);
 
(b)
Any fixed platform well with a casing pressure that is greater than 100 psig and that cannot bleed to 0 psig through a ½-inch needle valve within 24 hours, or is not bled to 0 psig during a casing diagnostic test;
 
(c)
Any well that has demonstrated tubing/casing, tubing/riser, casing/casing, riser/casing, or riser/riser communication;
 
(d)
Any well that has sustained casing pressure (SCP) and is bled down to prevent it from exceeding its MAWOP, except during initial startup operations described in §250.521;
 
(e)
Any hybrid well with casing or riser pressure exceeding 100 psig; or
 
(f)
Any subsea well with a casing pressure 100 psig greater than the external hydrostatic pressure at the subsea wellhead.

[76 FR 64462, Oct. 18, 2011. Redesignated at 77 FR 50894, Aug. 22, 2012]

   Reason: