§250.1006 — How must I decommission and take out of service a DOI pipeline?
 
(a)
The requirements for decommissioning pipelines are listed in §250.1750 through §250.1754.
 
(b)
The table in this section lists the requirements if you take a DOI pipeline out of service:
If you have the pipeline out of service for:Then you must:
(1) 1 year or less,Isolate the pipeline with a blind flange or a closed block valve at each end of the pipeline.
(2) More than 1 year but less than 5 years,Flush and fill the pipeline with inhibited seawater.
(3) 5 or more years,Decommission the pipeline according to §§250.1750-250.1754.