§75.205 — Installation of roof support using mining machines with integral roof bolters

When roof bolts are installed by a continuous mining machine with intregal roof bolting equipment:

 
(a)
The distance between roof bolts shall not exceed 10 feet crosswise.
 
(b)
Roof bolts to be installed 9 feet or more apart shall be installed with a wooden crossbar at least 3 inches thick and 8 inches wide, or material which provides equivalent support.
 
(c)
Roof bolts to be installed more than 8 feet but less than 9 feet apart shall be installed with a wooden plank at least 2 inches thick and 8 inches wide, or material which provides equivalent support.

   Reason: