§18.98 — Enclosures, joints, and fastenings; pressure testing
 
(a)
Cast or welded enclosures shall be designed to withstand a minimum internal pressure of 150 pounds per square inch (gage). Castings shall be free from blowholes.
 
(b)
Pneumatic field testing of explosion-proof enclosures shall be conducted by determining:
 
(1)
Leak performance with a peak dynamic or static pressure of 150 pounds per square inch (gage); or
 
(2)
A pressure rise and rate of decay consistent with unyielding components during a pressure-time history as derived from a series of oscillograms.
 
(c)
Welded joints forming an enclosure shall have continuous gastight welds.