Login required to View Regulations

Sign In or Register Now.  Registration is fast and free!

 
§7.102 — Exhaust gas cooling efficiency test
 
(a)
Test procedures.
 
(1)
Follow the procedures specified in §7.101(a).
 
(2)
Install a temperature measuring device to measure the exhaust gas temperature at discharge from the exhaust conditioner. The temperature measuring device shall be accurate to ±4 °F (±2 °C).
 
(3)
Determine the exhaust gas temperature at discharge from the exhaust conditioner before the exhaust gas is diluted with air.
 
(b)
Acceptable performance.
 
(1)
The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 °F (76 °C).
 
(2)
The exhaust gas temperature at discharge from a dry exhaust conditioner before the gas is diluted with air shall not exceed 302 °F (150 °C).

   Reason: